左心吸引压力监控技术用于心脏手术体外循环的效果

Efficacy of left heart attracting pressure monitoring technology applied in cardiopulmonary bypass in cardiac surgery

摘要目的:评价左心吸引压力监控技术用于心脏手术体外循环的效果。方法:择期在体外循环下行心脏瓣膜置换术的患者80例,性别不限,年龄40~64岁,体重50~80 kg,ASA分级Ⅱ~Ⅳ级,NYHA心功能分级Ⅱ或Ⅲ级,LVEF≥40%,采用随机数字表法分为2组( n=40):传统左心吸引组(T组)和左心吸引压力监控技术组(M组)。T组根据左心吸引量和术野清晰程度,调整左心吸引泵的转速;M组通过对左心吸引管内压力的实时监测,调整左心吸引泵的转速。吸闭恢复正常吸引后取左心回血,测定游离血红蛋白浓度。记录左心吸闭后调整次数、术中血红蛋白尿和术后吸引管沉淀物的发生情况。 结果:与T组比较,M组游离血红蛋白浓度、术中血红蛋白尿发生率和术后吸引管沉淀物发生率降低,左心吸闭后调整次数减少( P<0.05)。 结论:左心吸引压力监控技术可安全有效地用于心脏手术体外循环。

更多

abstractsObjective:To evaluate the efficacy of left heart attracting pressure monitoring technology applied in cardiopulmonary bypass (CPB) in cardiac surgery.Methods:Eighty patients of both sexes, aged 40-64 yr, weighing 50-80 kg, of American Society of Anesthesiologists physical status Ⅱ-Ⅳ, with New York Heart Association grade Ⅱ or Ⅲ, with left ventricular ejection fraction≥40%, undergoing elective cardiac valve replacement, were divided into 2 groups using a random number table method: traditional left heart aspiration group (T group) and modified left heart aspiration group (M group), with 40 patients in each group.The rotation speed of left ventricular suction pump was adjusted according to left ventricular suction volume and surgical field clarity in group T and by monitoring the pressure in the left suction tube in real time in group M. After aspiration returned to normal aspiration, blood of the left heart returned after aspiration was collected to determine the concentration of free hemoglobin.The number of adjustments after left ventricular aspiration, intraoperative hemoglobinuria, and occurrence of tissue sediment in the aspiration tube after operation were recorded.Results:Compared with T group, the concentration of free hemoglobin, incidence of intraoperative hemoglobinuria and incidence of tissue sediment in the aspiration tube after operation were significantly decreased, and the number of adjustments after left ventricular aspiration was decreased in M group ( P<0.05). Conclusion:Left heart attracting pressure monitoring technology can be safely and effectively applied in CPB in cardiac surgery.

More
广告
  • 浏览0
  • 下载0
中华麻醉学杂志

中华麻醉学杂志

2021年41卷8期

988-991页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷