高海拔环境下不同近红外光谱无创血红蛋白仪检测成功率的比较

Comparison of detection success rate of different kinds of near-infrared spectrum non-invasive hemoglobin monitors in high-altitude environments

摘要目的:比较高海拔环境下不同近红外光谱无创血红蛋白仪的检测成功率。方法:健康志愿者144名,性别不限,年龄18~50岁。采用随机数字表法分为3组:模拟海拔3 500 m组( n=35)、4 000 m组( n=55)和4 500 m组( n=54)。分别在平原环境和模拟不同海拔高度环境中,采用Radical-7、NW-9002SHM、A5和TensorTip MTX型血红蛋白仪检测血红蛋白,比较检测成功率,采用logistic回归分析法筛选影响仪器检测成功率的因素,并通过ROC曲线和约登指数确定阈值。 结果:在模拟3 500、4 000和4 500 m高海拔环境中,TensorTip MTX检测成功率高于Radical-7、NW-9002SHM和A5( P<0.001),Radical-7、NW-9002SHM和A5检测成功率差异无统计学意义( P>0.05)。低SpO 2是影响Radical-7、NW-9002SHM和A5型血红蛋白仪高海拔检测成功率的主要因素( P<0.001),判断其检测成功的SpO 2临界值分别为88.5%、87.5%和89.5%;TensorTip MTX检测成功率不受低SpO 2影响。 结论:TensorTip MTX型近红外光谱无创血红蛋白仪检测成功率受高海拔环境影响最小,在不具备吸氧条件下可优先选用;Radical-7、NW-9002SHM和A5型近红外光谱无创血红蛋白仪在高海拔环境中应用时需提高氧饱和度才能保证仪器有较高的检测成功率。

更多

abstractsObjective:To compare the detection success rates (DSRs) of different kinds of near-infrared spectrum non-invasive hemoglobin monitors in high-altitude environments.Methods:One hundred and forty-four healthy volunteers of either sex, aged 18-50 yr, were assigned to one of 3 groups using a random number table method: simulated high-altitude 3 500 meter group ( n=35), 4 000 meter group ( n=55) and 4 500 meter group ( n=54). Hemoglobin was detected by Radical-7, NW-9002SHM, A5 and TensorTip MTX type hemoglobin monitors in plain environment and simulated environment at different altitudes, and the DSRs were compared.Logistic regression analysis was conducted to identify the risk factors affecting the success rate of instrument detection, and the cut-off value was determined by ROC curve and the Youden index. Results:In the simulated high-altitude environment of 3500, 4000 and 4500 m, the DSR of TensorTip MTX was significantly higher than that of Radical-7, NW-9002SHM and A5 ( P<0.001), and there was no significant difference in the DSR among Radical-7, NW-9002SHM and A5 ( P>0.05). Low SpO 2 was the main factor affecting the DSRs of the Radical-7, NW-9002SHM and A5 type hemoglobin monitor in high-altitude environment ( P<0.001), and the cut-off value of SpO 2 in determining the success of detection was 88.5%, 87.5% and 89.5%, respectively.The DSR of TensorTip MTX was not affected by low SpO 2. Conclusions:The DSR of TensorTip MTX hemoglobin monitor is minimally affected by the high-altitude environment and can be preferred in the absence of oxygen supply; when Radical-7, NW-9002SHM or A5 hemoglobin monitor applied in high-altitude environments, oxygen saturation needs to be increased to ensure a high DSR.

More
广告
栏目名称
DOI 10.3760/cma.j.cn131073.20210908.00214
发布时间 2022-02-20(万方平台首次上网日期,不代表论文的发表时间)
  • 浏览102
  • 下载1
中华麻醉学杂志

中华麻醉学杂志

2022年42卷2期

190-194页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷