医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

帕金森病丘脑底核脑深部电刺激术术中及术后CT影像电极位置偏移特点分析

Displacement characteristics of intraoperative and postoperative positions of electrodes on CT imaging for subthalamic nucleus-deep brain stimulation in Parkinson's disease

摘要目的 探讨帕金森病(PD)丘脑底核脑深部电刺激术(STN-DBS)术中及术后CT影像上电极位置偏移特点. 方法 回顾性分析南方医科大学珠江医院神经外科自2014年1月至2018年6月收治的35例接受STN-DBS治疗的PD患者的术前MRI影像、术中及术后CT影像资料.以术前MRI为蓝本建立三维直角坐标系,运用MRI/CT融合技术将术中及术后CT影像与术前MRI融合,定位术中及术后电极位置,分析术中电极与术后电极位置坐标偏差,总结位置偏移特点.利用线性回归分析双侧的坐标偏差特点与对应变量间的相关性. 结果 双侧电极术后位置与术中位置的空间距离在1mm左右,深度(z轴)偏移极小.侧旁轴(x轴)上第1侧电极术后位置较术中位置向外偏移明显;第2侧电极向内偏移,偏移程度小.前后轴(y轴)上第1侧电极向后偏移明显;第2侧电极向后偏移较小.双侧电极中,术中电极-术前靶点、术后电极-术前靶点对应的三轴坐标偏差间均呈显著的线性正相关关系. 结论 STN-DBS术后电极位置与术中电极位置的偏移存在较为明显的规律,可指导术中电极的调整及推测术后电极位置.

更多

abstractsObjective To investigate the displacement characteristics of intraoperative and postoperative positions of electrodes on CT imaging for bilateral subthalamic nucleus-deep brain stimulation (STN-DBS) in Parkinson's disease (PD).Methods A retrospective analysis on preoperative MR imaging,intraoperative and postoperative CT images of 35 patients with PD treated with STN-DBS in our hospital from January 2014 to June 2018 was performed.A three-dimensional coordinate system was established based on preoperative MR imaging.MR imaging/CT fusion technique was used to fuse intraoperative and postoperative CT images with preoperative MR imaging to locate intraoperative and postoperative electrode positions.The displacement characteristics of intraoperative and postoperative electrodes were analyzed.Results The spatial distance between intraoperative and postoperative positions of bilateral electrodes was about 1 mm,and the depth displacement was minimal.The postoperative position of the first side electrode on lateral axis was shifted outwardly from intraopemtive position,and the second side electrode was shifted internally with a small degree;on anterior-posterior axis,the first side electrode obviously shifted backward,and the second side electrode slightly shifted backward.For bilateral electrodes,corresponding coordinate deviation of three axis between intraoperative electrode-preoperative target and postoperative electrode-preoperative target,showed a significant positive linear correlation,therefore,leading out the coordinate deviation regression function model.Conclusions The displacement of electrodes between intraoperative and postoperative positions has obvious rules after STN-DBS in PD,which can guide the adjustment of intraoperative electrode position and predict the postoperative position of electrode.

More
广告
  • 浏览199
  • 下载108
中华神经医学杂志

中华神经医学杂志

2018年17卷7期

678-684页

ISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷