食管高分辨率测压诊断内镜阴性食管源性胸痛的价值探讨
The value explore of endoscopic esophagus negative esophageal source chest pain by high resolution pressure diagnostic
摘要目的 探讨食管高分辨率测压、24 h食管pH值监测诊断内镜阴性食管源性胸痛的价值.方法 选择2012年10月至2013年10月231例非心源性胸痛患者,监测其食管测压及24h食管pH值.结果 食管测压及监测结果显示,无异常者131例(56.7%),异常者100例(43.3%).异常者中男51例,女49例,年龄20~ 70岁,平均年龄(55.1±10.9)岁.异常者中20例胡桃夹食管(20%),6例弥漫性食管痉挛(6%),5例贲门失弛缓症(5%),30例非特异性食管运动功能障碍(30%),32例胃食管反流病(32%),7例酸敏感食管(7%).结论 24 h食管pH监测对发现诊断食管源性胸痛作用显著,内镜阴性食管源性胸痛以胃食管反流病引起的最多.
更多相关知识
abstractsObjective To study the value explore of endoscopic esophagus negative esophageal source chest pain by high resolution pressure and 24 h esophageal pH monitoring diagnostic.Methods 231 cases with non cardiac chest pain were chosen between October 2012 to October 2013,and monitored the esophageal pressure and 24 h esophageal pH value.Results The results showed that there was no abnormality in 131 cases(56.7%),and abnormalities were found in 100 cases(43.3%),51 cases of male and 49 cases of female,average age was(55.1 ± 10.9) years.Nutcracker esophagus were 20 cases(20%),6 cases of diffuse esophageal spasm(6%),5 cases were cardiac relaxation loss(5%),30 cases were nonspecific esophageal motor dysfunction(30%),32 cases were gastroesophageal reflux disease(32%),7 cases were diagnosed as sensitive esophageal acid(7%).Conclusion 24 h esophageal pH monitoring has significantly effect on the diagnosis of esophageal source of chest pain,and negative esophageal source chest pain caused by gastroesophageal reflux disease is the most.
More相关知识
- 浏览292
- 被引3
- 下载254