医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

流式细胞术检测伊红-5′-马来酰亚胺标记红细胞在80例遗传性球形红细胞增多症中的诊断价值

Flow cytometric test using eosin-5′-maleimide (EMA) labelling of red blood for diagnosis of hereditary spherocytosis

摘要目的 探讨伊红-5′-马来酰亚胺(EMA)为标记流式细胞术检测遗传性球形红细胞的灵敏性和特异性,并对试剂和样本稳定性进行验证.方法 对80例遗传性球形红细胞增多症(HS)和44例非HS患者外周血样本全部采用EMA标记流式细胞术检测、红细胞渗透脆性试验和酸化甘油溶解试验三种方法进行检测,比较三种方法的灵敏性和特异性,探讨EMA标记流式细胞术检测的可行性.并观察EMA及样本在不同储存条件下的稳定性.结果 通过检测124例样本得出,EMA标记流式细胞术检测的灵敏性和特异性分别为0.925和0.954,红细胞渗透脆性试验分别为0.950和0.455,酸化甘油溶解试验为1.000和0.318.红细胞渗透脆性试验和酸化甘油溶解试验的灵敏性稍高于EMA流式检测方法,但特异性差,不能明确区分球形红细胞增多是否为HS.EMA对温度很敏感,-80℃储存180 d较4℃存储1d稳定.HS样本的稳定性较好,4℃放置6d、室温条件放置3d不会影响结果的判定.结论 EMA标记流式细胞术检测HS具有良好的灵敏性和特异性,-80℃储存EMA较为稳定,须在样本4℃放置6d内、室温条件放置3d内完成检测.

更多

abstractsObjective To investigate the sensitivity and specificity of eosin-5′-maleimide (EMA) assay for the diagnosis of hereditary spherocytosis (HS),and to verify the stability of reagent and samples.Methods EMA flow cytometry test,NaC1-osmotic fragility test and acidified glycerol lysis test were performed using peripheral blood samples from 80 patients with HS and 44 patients with other blood diseases,the sensitivity and specificity of the three methods were compared,and the feasibility of EMA binding test was estimated.The stability of EMA reagent and HS samples stored at different temperatures were tested.Results Among the 124 tested samples,the sensitivity and specificity of EMA binding test was 0.925 and 0.954,that of NaCl-osmotic fragility test was 0.950 and 0.455,and that of acidified glycerol lysis test was 1.000 and 0.318,respectively.Although the sensitivity of NaCl-osmotic fragility test and acidified glycerol lysis test was a little higher than that of EMA binding test,the specificity of the former two methods was poor,they couldn' t clearly distinguish whether spherocytosis is hereditary spherocytosis.The experiment results showed that EMA was sensitive to the temperature and shouldn't be stored in a small aliquots at-80 ℃ over a period of 6 months.The stability of the HS sample was better,6 days storage at 4 ℃ and 3 days storage at room temperature had no influence on the results.Conclusions EMA binding test by flow cytometry showed good sensitivity and specificity for HS diagnosis.EMA reagent should be stored at-80 ℃ and the HS samples should be tested within 6 days storage at 4 ℃ and 3 days at room temperature.

More
广告
  • 浏览951
  • 下载285
中华血液学杂志

中华血液学杂志

2015年36卷7期

598-601页

MEDLINEISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷