• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献>>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

准分子激光原位角膜磨镶术后OrbscanⅡ估算术前角膜屈光力

Estimation of preoperative corneal power in patients with myopic LASIK based on postoperative corneal data measured from Orbscan Ⅱ

摘要目的 比较OrbscanⅡ测量准分子激光原位角膜磨镶术(LASIK)前后周边角膜后表面曲率半径改变,初步确立新的角膜前后表面曲率半径比率R,利用术后周边后表面角膜曲率半径和比率R估算术前角膜总屈光力。方法 回顾分析OrbscanⅡ测量151只眼术前及术后3个月角膜7~10 mm区后表面曲率半径值的变化,计算角膜0~~7 mm区前表面曲率半径与角膜7~10 mm区后表面曲率半径比率R,利用比率R推算30只眼术前角膜总屈光力,并验证计算性角膜总屈光值与测量性角膜总屈光值的一致性。LASIK手术前后角膜7~10 mm后表面曲率半径变化和计算性角膜总屈光力与术前OrbscanⅡ测得角膜总屈光力比较采用配对t检验。结果 LASIK术前后角膜7~10 mm区后表面曲率半径差值为(-0.005±0.154)mm(t=0.417,P=0.677),术前角膜0~7 mm区前表面曲率半径与角膜7 ~ 10 mm区后表面曲率半径比率R为1.167±0.030,利用比率R推算的角膜总屈光力均值为(43.49±1.79)D,OrbscanⅡ测得实际角膜总屈光力均值为(43.77±1.53)D,两者差值均值为(-0.28±1.00)D(t=-1.523,P=0.139)。结论 LASIK手术前后周边区域角膜后表面曲率半径改变无实际临床意义,计算所得新角膜前后表面曲率半径比率R可准确的推算LASIK术者术前角膜总屈光力,为LASIK术后丢失术前资料患者双K法计算人工晶状体度数提供重要条件。

更多

abstractsObjective Compare the change of pre- and post-operative posterior corneal curvature measurements in peripheral fitting zones using the Orbscan Ⅱ topographer in patients undergoing myopic laser in situ keratomileusis (LASIK). To establish a new ratio of the anterior and posterior corneal curvature for the calculation of preoperative total corneal power using postoperative corneal data alone in patients after LASIK. Methods Retrospectively analyzed the changes of posterior corneal curvature in peripheral 7 to 10 mm fitting zones in 151 right eyes ( 151 individuals) 3 month after LASIK as measured by Orbscan Ⅱ. The new ratio between the anterior and posterior corneal curvature was measured. The new ratio was used to estimate pre-operative total corneal refractive power in 30 eyes. The estimated total corneal refractive power was compared with the value measured from Orbscan Ⅱ preoperatively. The accuracy of intraocular lens power estimated in 2 cases underwent cataract surgery after corneal refractive surgery was studied. Results The mean difference in estimated pre- and post-operative power of the posterior cornea was ( - 0. 005 ±0. 154 )mm (t = 0. 417, P = 0. 677). The ratio between the preoperative anterior central (0-7 mm) corneal curvature and the posterior peripheral (7 to 10 mm) corneal curvature was 1. 167 ±0. 030. Estimated mean pre-operative total corneal power was (43.49 ± 1.79 ) D, whereas the value measuring from Orbscan Ⅱ preoperatively was (43.77 ± 1.53 ) D. The mean difference between these two measurements was ( - 0. 28 ±1.00) D ( t = - 1. 523, P = 0. 139 ). The spherical equivalent refraction after cataract extraction of the two cases undertaken cataract surgery after corneal refractive surgery was 0. 54 D and 0. 69 D, respectively.Conclusions The difference in posterior corneal curvature measurement following myopic LASIK using the peripheral fitting zone with the Orbscan Ⅱ, as compared to the preoperative values, is clinically insignificant. The pre-LASIK corneal power can be estimated using post-LASIK data together with the new calculated ratio. This will be useful in post-LASIK patients requiring cataract surgery but without the availability of pre-LASIK corneal data for the estimation of the intraocular lens power.

More
广告
分类号 R779.63
栏目名称 论著
DOI 10.3760/cma.j.issn.0412-4081.2011.02.011
发布时间 2011-11-24
基金项目
温州市对外科技合作项目
  • 浏览308
  • 下载44
中华眼科杂志

中华眼科杂志

2011年47卷2期

151-155页

MEDLINEISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷