基于结构光扫描的多区域配准技术用于脊柱外科三维手术导航的试验研究

Experimental study of three dimensional navigation assisted spinal surgery by multi-segment registration technology based on structured light scanning

摘要目的 建立基于结构光扫描的脊柱手术导航配准系统.方法 获得胸椎模型的CT扫描图像及结构光扫描图像后,结合预配准与多区域迭代最近点(ICP)算法的精细配准方法,对CT图像及结构光图像进行配准.选择胸椎上4个区域进行不同组合,计算配准精度差异.对结构光扫描施加位移及三维正态噪声,观察配准精度变化.通过小牛脊柱标本进一步验证配准精度.结果 结合预配准与多区域配准的方法可实现脊椎骨可见光数据与CT数据的配准,选用两个及两个以上区域进行组合配准的误差<1 mm,结构光扫描受到干扰后,配准误差仍<1 mm.结论 基于结构光的预配准结合多区域配准算法可实现结构光数据与CT数据的配准,有着高精度、抗干扰能力强的优点,较传统的配准方法更为精确.

更多

abstractsObjective To study the registration method based on structured light scanning for navigation assisted spinal surgery and assess its accuracy so as to construct a registration system for the navigation assisted spinal surgery using structured light scanning. Methods Both the computed tomographic (CT) dataset and the structured light scanning images of thoracic vertebra were obtained. The preregistration and multi-segment iterative closest point (ICP) algorithm were used for the registration of CT images and structured light images. Four segmentations were selected from the surface of thoracic vertebra and placed into different combinations. The accuracy for each combination was studied. Noise and perturbation were exerted to structured light and registration accuracy was studied. And calf vertebra was used for further verification. Results A combination of pre-registration and multi-segment iterative closest point (ICP) algorithm was competent for the registration of CT scanning data and the structured light scanning data. The registration error was less than 1 mm when two and more segments were selected for registration combination. The registration error was less than 1 mm when noise was exerted. Conclusion With a high accuracy and a perturbation resistance, a combination of pre-registration and multi-segment registration algorithm based on structured light scanning is competent for the registration of CT scanning data and structured light scanning data.

More
广告
分类号 R6(外科学)
栏目名称
DOI 10.3760/cma.j.issn.0376-2491.2011.09.017
发布时间 2011-06-06(万方平台首次上网日期,不代表论文的发表时间)
基金项目
国家自然科学基金(60873187)
  • 浏览322
  • 下载24
中华医学杂志

中华医学杂志

2011年91卷9期

634-638页

MEDLINEISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷