医学文献 >>
  • 检索发现
  • 增强检索
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
默认
×
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

加速度传感器定量电生理测定对帕金森震颤与原发性震颤的鉴别诊断效果

Evaluating the electrophysiological features of tremor in Parkinson's disease and essential tremor using accelerometry

摘要目的 通过加速度传感器定量电生理测定研究帕金森病(PD)和原发性震颤(ET)患者左右两侧肢体震颤幅度、震颤频率、频谱宽度的特征.方法 回顾性分析并比较2015年5月至2016年4月在浙江大学附属第二医院门诊就诊的伴有震颤型帕金森病患者35例,原发性震颤患者40例,通过加速度传感器测定震颤程度不同的35例帕金森震颤(PT)患者和40例原发性震颤患者的震颤幅度、震颤频率、震颤频谱宽度以及负重对其影响,以总结两组患者的电生理学特点.结果 在静止状态、姿势状态和负重状态下,帕金森病平均振幅震颤弱的一侧比震颤强的一侧震颤幅度小,弱侧分别为(147±32)、(142±36)、(157±40) μV,强侧分别为(185±41)、(164±29)、(190±33) μV;原发性震颤组平均振幅震颤弱的一侧也比震颤强的一侧震颤幅度小,弱侧分别为(149±33)、(157±33)、(169±43) μV,强侧分别为(176±39)、(189±39)、(213±36)μV.在静止状态、姿势状态和负重状态下,震颤峰值频率帕金森病组震颤弱的一侧比震颤强的一侧快,弱侧分别为(6.1±1.1)、(6.4±1.7)、(6.5±2.0) Hz,强侧分别为(5.4±1.3)、(5.5±1.1)、(5.7±1.1) Hz,原发性震颤组震颤弱的一侧和震颤强的一侧震颤峰值频率接近,弱侧分别为(6.5±1.3)、(7.0±1.2)、(7.2±1.5) Hz,强侧分别为(7.0±1.0)、(7.3±1.0)、(7.6±1.1) Hz.在静止状态和姿势状态下,震颤频谱宽度帕金森病组震颤弱的一侧较震颤强的一侧宽,弱侧分别为(2.1±0.6)、(2.4±1.1) Hz,强侧分别为(1.6±0.8)、(1.7±0.9) Hz,但是在负重状态下,两侧频谱宽度接近,弱侧为(2.3±1.2)Hz,强侧为(2.2±1.1) Hz;在静止状态、姿势状态和负重状态下,原发性震颤组频谱宽度震颤弱的一侧同震颤强的一侧接近弱侧分别为(2.0±1.1)、(2.2±0.9)、(1.9±1.0) Hz,强侧分别为(1.8±0.6)、(1.9±0.8)、(2.1±0.7)Hz.结论 帕金森病组和原发性震颤组患者震颤幅度均存在不对称性;帕金森病患者震颤峰值频率是不对称的,频谱宽度存在不对称性,而原发性震颤患者是对称的,通过加速度传感器测定的震颤参数能够用来区分帕金森病和原发性震颤患者.

更多

abstractsObjective To investigate the electrophysiological features of tremor intensity,frequency and frequency dispersion of Parkinsonian (PT group) and essential (ET group) tremors using accelerometry.Methods The amplitude,frequency and frequency dispersion of rest tremor,postural tremor and the influence of weight on tremor of 35 PT patients and 40 ET patients in Department of Neurology,the Second Affiliated Hospital Zhejiang University School of Medicine from May 2015 to April 2016 were retrospectively analyzed and compared.Data of the more and less trembling hands were statistically elaborated.Results In resting,postural and loading states,PT amplitudes of the less affected hand were smaller than the more affected one.The less affected hand were (147 ± 32),(142 ± 36),(157 ±40)μV,the more affected hand were (185 ±41),(164 ± 29),(190 ± 33)μV,respectively;ET amplitudes of the less affected hand were also smaller than the more affected one,and the less affected hand were (149 ± 33),(157 ± 33),(169 ± 43) μV,the more affected hand were (176 ± 39),(189 ± 39),(213 ±36)μV,respectively;PT frequencies of the less affected hand were faster than the more affected one,with the less affected hand (6.1 ± 1.1),(6.4 ± 1.7),(6.5 ± 2.0) Hz,the more affected hand (5.4 ± 1.3),(5.5 ± 1.1),(5.7 ± 1.1) Hz,respectively,but ET frequencies of the less affected hand were similar to the more affected one,with the less affected hand (6.5 ± 1.3),(7.0 ± 1.2),(7.2 ± 1.5) Hz,the more affected hand (7.0 ± 1.0),(7.3 ± 1.0),(7.6 ± 1.1) Hz,respectively;in resting and postural states,PT frequency dispersions of the less affected hand were broader than the more affected one,the less affected hand were (2.1 ± 0.6),(2.4 ± 1.1) Hz,respectively;the more affected hand were (1.6 ± 0.8),(1.7 ± 0.9) Hz,respectively.But in loading state,PT frequency dispersions were similar in both sides (2.3 ± 1.2,2.2 ± 1.1) Hz;In resting,postural and loading states,ET frequency dispersions were also similar in both two sides,the less affected hand were (2.0 ± 1.1),(2.2 ± 0.9),(1.9 ± 1.0) Hz,the more affected hand were (1.8 ± 0.6),(1.9 ± 0.8),(2.1 ± 0.7) Hz.Conclusions Tremor intensity is significantly asymmetric both in PT and ET,while frequency and frequency dispersion are symmetric in ET but asymmetric in PT.Bilateral assessment of frequency related tremor parameters may be useful for differentiating ET from PT.

More
广告
  • 浏览349
  • 下载146
中华医学杂志

中华医学杂志

2016年96卷41期

3289-3293页

MEDLINEISTICPKUCSCDCA

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new医文AI 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷