Microwave ablation: results in ex vivo and in vivo porcine livers with 2450-MHz cooled-shaft antenna

摘要:

Background Imaging-guided thermal ablation using different energy sources continues to gain favor as a minimally invasive technique for the treatment of primary and metastatic hepatic malignant tumors.This study aimed to evaluate the performance of microwave ablation with 2450-MHz internally cooled-shaft antenna in ex vivo and in vivo porcine livers.Methods All studies were animal care and ethics committee approved.Microwave ablation was performed using a noncooled or cooled-shaft antenna in 23 ex vivo (92 ablations) and eight in vivo (36 ablations) porcine livers.Diameters of the coagulation zone were observed on gross specimens.The coagulation diameters achieved in different microwave ablation parameter groups were compared.Curve estimation analysis was performed to characterize the relationship between applied power and treatment duration and coagulation diameter (including short-axis and long-axis diameter).Results Coagulation zones were elliptical and an arrowed-shaped carbonization zone around the shaft was observed in all groups.But the antenna track was also coagulated in the noncooled-shaft antenna groups.In ex vivo livers,the short-axis diameter correlated with the power output in a quadratic curve fashion (R2=0.95) by fixing ablation duration to 10 minutes,and correlated with the ablation duration in a logarithmic curve fashion (R2=0.98) by fixing power output to 80 W.The short-axis reached a relative plateau within 25 minutes.In in vivo livers,short-axis diameter correlated with the coagulation duration in a sigmoidal curve fashion (60 W group R2=0.76,80 W group R2=0.87),with a relative plateau achieved within 10 minutes for power settings of 60 W and 80 W.Conclusions The internally cooled microwave antenna may be advantageous to minimize collateral damage.The short-axis diameter enlargement has a plateau by fixing power output.

更多
期刊: 《中华医学杂志(英文版)》2011年124卷20期 3386-3393页 SCIMEDLINEISTICCSCDBP
分类号: R1
栏目名称: ORIGINAL ARTICLES
DOI: 10.3760/cma.j.issn.0366-6999.2011.20.032
发布时间: 2012-01-12
翻译满意度评价:
提交
  • 浏览:200
  • 下载:4

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷