• 医学文献
  • 知识库
  • 评价分析
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
  • 临床诊疗知识库
  • 中医药知识库
  • 机构
  • 作者
热搜词:
换一批
论文 期刊
取消
高级检索

检索历史 清除

医学文献 >>
  • 全部
  • 中外期刊
  • 学位
  • 会议
  • 专利
  • 成果
  • 标准
  • 法规
知识库 >>
  • 临床诊疗知识库
  • 中医药知识库
评价分析 >>
  • 机构
  • 作者
热搜词:
换一批

Screening for amblyopia among grade-1 students in primary school with uncorrected vision and stereopsis test in central China

摘要:

Background Screening for amblyopia at earliest is important for early treatment and better prognosis.This study aimed to evaluate the validity of uncorrected distant and near visual acuity (VA) and stereoacuity for screening amblyopia in grade-1 students in primary school in central China.Methods By stratified cluster sampling,3112 grade-1 students from 11 Anyang primary schools were selected for the study.All the participants underwent uncorrected distant and near VA,stereopsis test,cycloplegic refraction,best corrected VA (BCVA),cover test,and ocular movement examination.VA was measured with a logarithm of the minimum angle of resolution (IogMAR) chart.Stereoacuity was measured with the Lang Ⅱ stereo card and TNO test.Amblyopia was defined as the BCVA less than or equal to 0.1 IogMAR units of any eye in the absence of significant pathological abnormalities.The sensitivity,specificity,and positive and negative predictive value of uncorrected VA and stereoacuity for amblyopia were analyzed.Results Out of the 3112 eligible students,2893 (92.96%) completed the examinations.The average age of the students was (7.10±0.41) years.Screened by distant VA with low cutoff (IogMAR 0.1),high cutoff (IogMAR 0.0),and near VA (IogMAR 0.0),31.64%,73.18%,and 50.23% students were abnormal,respectively.Screened by stereopsis test,only 4.69% students were abnormal.Diagnosed by a senior pediatric ophthalmologist,61 students had amblyopia.The sensitivities of distant VA with low/high cutoff and near VA were 92.31%,100%,and 80.77%,respectively,whereas that of stereoacuity by TNO test was 15.38%.Simultaneous testing of either two of the three tests improved the sensitivity.Conclusions Distant VA test of high cutoff alone displays a high sensitivity but a low specificity.Simultaneous testing of distant VA of low cutoff and stereoacuity is a better choice to balance between sensitivity and specificity.

更多
作者单位: Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology and Visual Science Key Laboratory, Beijing 100730, China [1] Anyang Eye Hospital, Anyang, Henan 455000, China [2]
期刊: 《中华医学杂志(英文版)》2013年126卷5期 903-908页 SCIMEDLINEISTICCSCDBP
栏目名称: ORIGINAL ARTICLES
DOI: 10.3760/cma.j.issn.0366-6999.20123256
发布时间: 2013-04-26
基金项目:
This study was supported by grants from the Major State Basic Research Development Program of China the Major International (Regional) Joint Research Project (No.81120108807) of the National Natural Science Foundation of China
翻译满意度评价:
提交
  • 浏览:184
  • 下载:8

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷