人源化抗 VEGF 单克隆抗体制品的大小异质性分析

Size heterogeneity analysis of monoclonal antibody products

摘要目的:比较十二烷基磺酸钠聚丙烯酰胺凝胶电泳( sodium dodecyl sulfatepolyacrylam-ide gel electrophoresis ,CE-SDS)和分子排阻高效液相( size exclusion high performance liquid chromatogra-phy,SE-HPLC)在单克隆抗体(单抗)大小异质性分析中的区别。方法应用非还原和还原CE-SDS以及常规、变性和变性还原SE-HPLC评价人源化抗血管内皮细胞生长因子( VEGF)单抗的大小异质性。结果对于多聚体的分析,虽然非还原CE-SDS结果显示其含量为0.82%±0.01%,显著低于常规SE-HPLC的分析结果(5.08%±0.10%),但与变性SE-HPLC的分析结果(1.05%±0.02%)则基本一致;在非还原状态下对单抗的片段分析,非还原CE-SDS结果显示其含量为7.12%±0.04%,显著高于常规SE-HPLC的分析结果(0.02%±0.01%)以及变性SE-HPLC的分析结果(0.62%±0.01%);而在还原状态下对单抗的片段分析,还原CE-SDS结果显示其含量为(3.19%±0.50%),其含量同样高于变性还原SE-HPLC的分析结果(0.07%±0.01%)。结论在分析多聚体含量时,由于常规SE-HPLC对共价和非共价连接的多聚体形式均可显示,相比CE-SDS相比更加客观;而在分析片段含量时,非还原CE-SDS可显示非共价键连接的片段,还原CE-SDS可显示降解片段,所以CE-SDS相比常规SE-HPLC更具优势。两种不同原理分析方法的组合有效保障了单抗制品大小异质性的质量控制。

更多

abstractsObjective To compare the capability of capillary electrophoresis-sodium dodecyl sul-fate ( CE-SDS) and size exclusion-high performance liquid chromatography ( SE-HPLC) for analysis of size heterogeneity of monoclonal antibody products .Methods The size heterogeneity of one humanized anti-VEGF monoclonal antibody was analyzed by using non-reduced and reduced CE-SDS, and conventional , de-natured and denatured reduced SE-HPLC.Results The percentage of aggregates detected by non-reduced CE-SDS (0.82%±0.01%) was equal to that by using denatured SE-HPLC (1.05%±0.02%), but it was significantly lower than that by using conventional SE-HPLC analysis (5.08%±0.10%).With regard to fragments analyzed with non-reduced antibodies, its percentage was (7.12±0.04)% measured by non-re-duced CE-SDS analysis that was significantly higher than that by conventional SE -HPLC analysis (0.02%± 0.01%) and denatured SE-HPLC analysis (0.62%±0.01%).Using reduced antibodies , the percentage of fragments was (3.19±0.50)%tested by reduced CE-SDS analysis that was significantly higher than that by using denatured reduced SE-HPLC analysis (0.07%±0.01%).Conclusion Conventional SE-HPLC was more objective than CE-SDS for content analysis of aggregates , as both the covalent and non-covalent forms of aggregates could be detected .Non-reduced CE-SDS could demonstrate the content of clips , while reduced CE-SDS showed the degraded fragments .Therefore, CE-SDS had an advantage over conventional SE-HPLC for content analysis of fragments .The use of the two analytical methods in combination provided solid techni-cal supports for the quality control of size heterogeneity of monoclonal antibodies .

More
广告
栏目名称
DOI 10.3760/cma.j.issn.0254-5101.2014.09.013
发布时间 2014-10-24(万方平台首次上网日期,不代表论文的发表时间)
基金项目
  • 浏览684
  • 下载25
中华微生物学和免疫学杂志

加载中!

相似文献

  • 中文期刊
  • 外文期刊
  • 学位论文
  • 会议论文

加载中!

加载中!

加载中!

加载中!

扩展文献

法律状态公告日 法律状态 法律状态信息

特别提示:本网站仅提供医学学术资源服务,不销售任何药品和器械,有关药品和器械的销售信息,请查阅其他网站。

  • 客服热线:4000-115-888 转3 (周一至周五:8:00至17:00)

  • |
  • 客服邮箱:yiyao@wanfangdata.com.cn

  • 违法和不良信息举报电话:4000-115-888,举报邮箱:problem@wanfangdata.com.cn,举报专区

官方微信
万方医学小程序
new智医 翻译 充值 订阅 收藏 移动端

官方微信

万方医学小程序

使用
帮助
Alternate Text
调查问卷